A Retrospective, Multicenter, Cross-Sectional Case Series Study Evaluating Outcomes of CAD/CAM Abutments on Implants from Four Manufacturers: 4-Year Mean Follow-up

Christopher A. Barwacz, Kumar C. Shah, Nurit Bittner, William Parker, Toni T. Neumeier, Ghadeer N. Thalji, Ingeborg J. De Kok

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)

Abstract

Purpose: To evaluate the clinical, radiographic, and prosthetic outcomes of a single custom CAD/CAM abutment system on implants from four manufacturers, with a mean clinical service of 4 years in a retrospective, multicenter case series study. Materials and Methods: Adult subjects (n = 142) previously restored with titanium or gold-shaded titanium nitride custom CAD/CAM abutments (Atlantis, Dentsply Sirona; n = 259) connected to implants from four different manufacturers (Dentsply Sirona Implants [AT], Biomet 3i [BM], Nobel Biocare [NB], Straumann [ST]), irrespective of implant-abutment interface, and replacing one or more teeth in any position were recalled for a single-visit examination by calibrated investigators at six university clinics. The primary outcomes evaluated included abutment success and survival; secondary outcomes included assessment of papillae fill, probing pocket depth (PD), bleeding on probing (BOP), marginal bone levels (MBLs), and patient-reported outcome measures (PROMs). Results: Two-hundred fifty-five (98.5%) abutments supported cement-retained restorations, and four (1.5%) abutments supported screw-retained restorations. Forty-two patients had 64 AT implants (25%), 31 patients had 61 BM implants (24%), 26 patients had 50 NB implants (19%), and 43 patients had 84 ST implants (32%). The overall implant-CAD/CAM abutment success rate was 92.66% (95% CI: 88.78%, 95.53%) for all implants examined, and the survival rate was 98.84% (95% CI: 96.65%, 99.76%) for all implants evaluated. The Jemt papillae index demonstrated a minimum of at least 50% to complete fill of the interproximal papillae in 65.0% of sites. PDs had a median value of 3.0 mm, and BOP was present on 19% of abutment surfaces. Mean MBL changes from the time of placement to exam were -0.24 ± 0.99 mm (-4.9 to 2.3; P =. 058) for mesial sites and -0.32 ± 0.96 mm (-4.9 to 2.1; P =. 000) for distal sites. PROMs expressed 93% of patients reporting good to very good masticatory function, 97% of patients reporting being satisfied or very satisfied with their esthetic outcomes, and 94% of patients indicating that they were satisfied or very satisfied with their overall implant-restorative outcomes.

Original languageEnglish
Pages (from-to)966-976
Number of pages11
JournalInternational Journal of Oral and Maxillofacial Implants
Volume36
Issue number5
DOIs
Publication statusPublished - 2021

Bibliographical note

Publisher Copyright:
© 2021. Quintessence Publishing Co Inc. All Rights Reserved.

Funding

This study was supported by Dentsply Sirona Implants. The authors reported no conflicts of interest related to this study.

ASJC Scopus Subject Areas

  • Oral Surgery

Fingerprint

Dive into the research topics of 'A Retrospective, Multicenter, Cross-Sectional Case Series Study Evaluating Outcomes of CAD/CAM Abutments on Implants from Four Manufacturers: 4-Year Mean Follow-up'. Together they form a unique fingerprint.

Cite this