Effect of Vancomycin Soaking on Anterior Cruciate Ligament Graft Biomechanics

Joseph D. Lamplot, Joseph N. Liu, Ian D. Hutchinson, Tony Chen, Hongsheng Wang, Amanda Wach, Scott A. Rodeo, Russell F. Warren

Research output: Contribution to journalArticlepeer-review

18 Citations (Scopus)

Abstract

Purpose: To evaluate the effect of soaking of anterior cruciate ligament (ACL) grafts in vancomycin solution on graft biomechanical properties at the time of implantation. Methods: The central third of patellar tendons was harvested from mature bovine knees and prepared as a tendon-only graft or a bone-tendon-bone (BTB) graft. Tendons were wrapped in gauze soaked in vancomycin solution (VS) (5 mg/mL) or normal saline (NS) and left to stand for 30 minutes at room temperature, simulating graft exposure times in the operating room during ACL reconstruction. Tensile testing was carried out on a materials testing system with (1) low-magnitude loading (60 N at 3 mm/s) with repeated testing of tendon-only grafts; and (2) high-magnitude loading (600 N at 10 mm/min) of BTB grafts. For tendon-only grafts, specimens were first wrapped in NS-soaked gauze and underwent testing, with repeated testing performed after wrapping in gauze soaked in VS or buffered VS (pH 7.0). For BTB grafts, specimens were randomly assigned to treatment with VS or NS. Results: For tendon-only grafts, there was no difference in Young's modulus (YM) after soaking with VS soaking (baseline, 12.69 MPa; treatment, 16.07 ± 4.44 MPa; P =.99) or buffered VS (baseline, 12.45 ± 4.55 MPa; treatment, 15.56 ± 2.83 MPa; P =.99). For BTB grafts, there were no differences in elongation strain (VS, 46.8% ± 7.0%; NS, 31.5% ± 13.5%, P =.19) or YM (VS, 158.4 ± 15.8 MPa; NS, 158.5 ± 23.3 MPa, P =.99). Conclusions: According to controlled biomechanical tests, vancomycin soaking of patellar tendon grafts does not adversely affect time-zero material properties. Clinical Relevance: This study suggests that vancomycin wrapping has no immediate adverse effects on the biomechanical properties of ACL grafts. Randomized controlled trials are warranted to validate the widespread use of vancomycin soaking of tendon grafts for infection prophylaxis during ACL reconstruction.

Original languageEnglish
Pages (from-to)953-960
Number of pages8
JournalArthroscopy - Journal of Arthroscopic and Related Surgery
Volume37
Issue number3
DOIs
Publication statusPublished - Mar 2021

Bibliographical note

Publisher Copyright:
© 2020 Arthroscopy Association of North America

Funding

The authors report the following potential conflicts of interest or sources of funding: J.N.L. reports personal fees, Smith & Nephew. T.C. is the Director of Scientific Affairs, AGelity Biomechanics, and reports equity, AGelity Biomechanics. R.F.W. reports personal fees and other, Orthonet. S.A.R. reports personal fees, Advance Medical, Ortho RTI. Full ICMJE author disclosure forms are available for this article online, as supplementary material.

FundersFunder number
Ortho RTI

    ASJC Scopus Subject Areas

    • Orthopedics and Sports Medicine

    Fingerprint

    Dive into the research topics of 'Effect of Vancomycin Soaking on Anterior Cruciate Ligament Graft Biomechanics'. Together they form a unique fingerprint.

    Cite this