T1 - Assessment of rotator cuff repair integrity using ultrasound and magnetic resonance imaging in a multicenter study
AU - Codsi, Michael J.
AU - Rodeo, Scott A.
AU - Scalise, Jason J.
AU - Moorehead, Tara Mc Donnell
AU - Ma, C. Benjamin
N1 - Publisher Copyright:
© 2014 Journal of Shoulder and Elbow Surgery Board of Trustees.
PY - 2014
Y1 - 2014
N2 - This study compared ultrasound and magnetic resonance imaging (MRI) evaluation of the repaired rotator cuff to determine concordance between these imaging studies. Methods: We performed a concordance study using the data from a prospective nonrandomized multicenter study at 13 centers. A suture bridge technique was used to repair 113 rotator cuff tears that were between 1 and 4 cm wide. Repairs were evaluated with MRI and ultrasound at multiple time points after surgery. The MRI scans were read by a central radiologist and the surgeon, and the ultrasounds were read by a local radiologist or the surgeon who performed the ultrasound. Results: The concordance between the central radiologist's MRI reading and the investigator's MRI readings at all time points was 89%, with a κ coefficient of 0.60. The concordance between the central radiologist's MRI and ultrasound readings at all time points was 85%, with a κ coefficient of 0.40. The concordance between the investigator's MRI and ultrasound readings was 92%, with a κ coefficient of 0.70. Conclusions: In the community setting, ultrasound may be used to evaluate the integrity of a repaired rotator cuff tendon and constitutes a comparable alternative to MRI when evaluating the integrity of a rotator cuff repair. Clinical investigators should compare their postoperative ultrasound results with their postoperative MRI results for a certain time period to establish the accuracy of ultrasound before relying solely on ultrasound imaging to evaluate the integrity of their rotator cuff repairs.
AB - This study compared ultrasound and magnetic resonance imaging (MRI) evaluation of the repaired rotator cuff to determine concordance between these imaging studies. Methods: We performed a concordance study using the data from a prospective nonrandomized multicenter study at 13 centers. A suture bridge technique was used to repair 113 rotator cuff tears that were between 1 and 4 cm wide. Repairs were evaluated with MRI and ultrasound at multiple time points after surgery. The MRI scans were read by a central radiologist and the surgeon, and the ultrasounds were read by a local radiologist or the surgeon who performed the ultrasound. Results: The concordance between the central radiologist's MRI reading and the investigator's MRI readings at all time points was 89%, with a κ coefficient of 0.60. The concordance between the central radiologist's MRI and ultrasound readings at all time points was 85%, with a κ coefficient of 0.40. The concordance between the investigator's MRI and ultrasound readings was 92%, with a κ coefficient of 0.70. Conclusions: In the community setting, ultrasound may be used to evaluate the integrity of a repaired rotator cuff tendon and constitutes a comparable alternative to MRI when evaluating the integrity of a rotator cuff repair. Clinical investigators should compare their postoperative ultrasound results with their postoperative MRI results for a certain time period to establish the accuracy of ultrasound before relying solely on ultrasound imaging to evaluate the integrity of their rotator cuff repairs.
UR - http://www.scopus.com/inward/record.url?scp=84922018939&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84922018939&partnerID=8YFLogxK
U2 - 10.1016/j.jse.2014.01.045
DO - 10.1016/j.jse.2014.01.045
M3 - Article
C2 - 24751529
AN - SCOPUS:84922018939
SN - 1058-2746
VL - 23
SP - 1468
EP - 1472
JO - Journal of Shoulder and Elbow Surgery
JF - Journal of Shoulder and Elbow Surgery
IS - 10
ER -