Frictional properties of the meniscus improve after scaffold-augmented repair of partial meniscectomy: A pilot study

Natalie K. Galley, Jason P. Gleghorn, Scott Rodeo, Russell F. Warren, Suzanne A. Maher, Lawrence J. Bonassar

Résultat de rechercheexamen par les pairs

35 Citations (Scopus)

Résumé

Background: To prevent further degeneration, it is desirable to fill a meniscal defect with a supportive scaffold that mimics the mechanics of native tissue. Degradable porous scaffolds have been used, but it is unclear whether the tissue that fills the site of implantation is mechanically adequate, particularly with respect to frictional performance. Questions/purposes: We therefore determined the frictional behavior of native and engineered meniscal replacement tissue from in vivo implantation over time. Methods: We evaluated boundary and mixed-mode friction coefficients of tissue generated in porous polyurethane scaffolds used to augment the repair of the meniscus of 13 skeletally mature sheep after partial meniscectomy. Implants were removed for evaluation at 3, 6, and 12 months. The friction coefficient, aggregate modulus, and hydraulic permeability were evaluated for tissue harvested from native meniscus adjacent to the implants, native meniscus from the intact contralateral knee, and repair tissue from the site of the scaffold implantation. The equilibrium friction coefficient (μ eq ) was measured in the presence of a lubricant bath of either phosphate-buffered saline (PBS) or equine synovial fluid (ESF). Results: Boundary μ eq in PBS of engineered meniscus improved with time and was similar to native tissue after 6 months. ESF enhanced lubrication for all samples at nearly all time points demonstrating the efficacy of ESF as a joint lubricant for repair tissue as well as native meniscus. Modulus increased and permeability decreased with implantation, likely as a result of tissue ingrowth. Conclusions: Promoting tissue ingrowth into porous scaffolds is a potential strategy for improving friction performance in meniscal repair.

Langue d'origineEnglish
Pages (de-à)2817-2823
Nombre de pages7
JournalClinical Orthopaedics and Related Research
Volume469
Numéro de publication10
DOI
Statut de publicationPublished - oct. 2011

Financement

One or more of the authors (NKG, JPG, SR, RW, LJB) received funding from Orteq Bioengineering, Inc, NSERC (NKG), FQRNT (NKG), and NASA (JPG). Each author certifies that appropriate approval for the animal protocol for this investigation was obtained at all institutions involved and that all investigations were conducted in conformity with ethical principles of research. This work was performed at Cornell University, Ithaca, NY, USA and Hospital for Special Surgery, New York, NY, USA.

Bailleurs de fondsNuméro du bailleur de fonds
Orteq Bioengineering, Inc
National Aeronautics and Space Administration
Natural Sciences and Engineering Research Council of Canada
Fonds Québécois de la Recherche sur la Nature et les Technologies

    ASJC Scopus Subject Areas

    • Surgery
    • Orthopedics and Sports Medicine

    Empreinte numérique

    Plonger dans les sujets de recherche 'Frictional properties of the meniscus improve after scaffold-augmented repair of partial meniscectomy: A pilot study'. Ensemble, ils forment une empreinte numérique unique.

    Citer